Spacer dampers

Type Conductor diameter [mm] L [mm] A [mm] B [mm] C [mm] Weight [kg] Farba/Color
237395 21.0 - 23.0 400 85 1100 7.87 5.00 modrá / blue
237396 23.0 - 26.0 400 85 1100 7.87 5.00 zelená / green
237397 26.0 - 30.6 400 85 1200 7.87 5.15 červená / red
237397.1 26.3 - 27.9 400 85 1200 7.87 5.15 červená / red

 

Material
Aluminium alloy, technical rubber
Use
Attachment of 3-bundled conductors at the overhead line with damping effect.
Note
For another diameter of the conductor, please contact us.

 

 

Type Náhrada za typ Conductor diameter [mm] Weight [kg]
237384.5 237384.1* 22.7 - 24.2 4.00
237386.5 237386.1* 25.7 - 27.1 3.99
237387.5 237387.1* 27.2 - 28.6 3.98
237388.6 237388.1* 28.7 - 30.1 4.04
237389.5 237389.1* 30.2 - 31.6 4.03
237390.5 --- 31.7 - 33.1 4.02
237393.5 237393.1* 35.9 - 37.2 4.45
237388.7 237388.5* 40.9 - 42.4 4.50

 

Material
Aluminium alloy, steel, technical rubber
Surface protection
Steel hot dip galvanized
Use
Attachment of 3-bundled conductors at the overhead line with damping effect.
Note
*anticorrosive jointing material

 

 

Type Conductor diameter [mm] L [mm] Weight [kg]
237403 28.0 - 31.0 400 4.0
237403.2 25.1 - 28.0 400 2.60
237403.5 31.7 450 4.12
237403.6 25.5 - 26.5 400 3.85

 

Material
Aluminium alloy, steel, technical rubber
Surface protection
Steel hot dip galvanized
Use
Attachment of 2-bundled or 3-bundled conductors at the overhead line. Type 237 403 is designed to attach the bundled conductors in connection with counterweight 2×20 kg type 229 503
Note
*anticorrosive jointing material

 

 

Type Conductor diameter [mm] L [mm] Weight [kg]
237212 18.3 - 20.4 400 2.0
237235 26.5 - 26.8 400 1.9
237245 28.7 - 29.8 400 1.9
237267 35.8 - 36.5 400 1.9
237212.1 20.4 - 22.4 400 2.0
237425 41.2 - 42.2 500 1.68
237426 41.2 - 42.2 400 1.5
237427 28.0 - 31.0 400 1.2

 

Material
Aluminium alloy, steel, technical rubber
Surface protection
Steel hot dip galvanized
Use
Attachment of 2-bundled conductors at the overhead line with damping effect.
Note
*anticorrosive jointing material

 

 

Type Náhrada za typ Conductor diameter [mm] L [mm] Weight [kg]
237286.4 237286.1* 25.7 - 27.1 400 2.90
237288.4 237288.1* 28.7 - 30.1 400 2.90
237289.5 237289.1* 30.2 - 31.6 400 2.85
237290.5 237290.4* 31.7 - 33.1 400 2.85
237292.5 237292.1* 34.7 - 36.2 400 2.85
237292.6 237292.4* 35.9 - 37.2 400 2.85

 

Material
Aluminium alloy, steel, technical rubber
Surface protection
Steel hot dip galvanized
Use
Attachment of 2-bundled conductors at the overhead line with damping effect.
Note
*anticorrosive jointing material

 

 

Type Conductor diameter [mm] a [mm] b [mm] L [mm] L1 [mm] Weight [kg]
9102647 29.31 435 2450 9480 - 10980 3711 - 5211 110.15

 

Material
Al-alloy, steel, stainless steel, EPDM
Surface protection
Steel hot dip galvanized
Use
Interfacial spacer dampers are used on overhead lines in situations, where is not able to keep necessary distance between conductors mainly from following reasons: during the building or construction of the lines with themselues could be reduced appliciated distances between conductors, for existing lines are assembled on the places with enhanced risk of frost cover, which caused enormous galloping of the conductors at her release.
Note
In cooperation with the project manager of the line we can develope variant according to the concrete line.

 

 

Type Conductor diameter [mm] a [mm] b [mm] L [mm] L1 [mm] Weight [kg]
9102112 29.31 450 2435 10570 - 11320 4800 - 5550 90.3

 

Material
Al-alloy, steel, stainless steel, EPDM
Surface protection
Steel hot dip galvanized
Use
Interfacial spacer dampers are used on overhead lines in situations, where is not able to keep necessary distance between conductors mainly from following reasons: during the building or construction of the lines with themselues could be reduced appliciated distances between conductors, for existing lines are assembled on the places with enhanced risk of frost cover, which caused enormous galloping of the conductors at her release.
Note
In cooperation with the project manager of the line we can develope variant according to the concrete line.

 

 

Type Conductor diameter [mm] a [mm] b [mm] L [mm] L1 [mm] Weight [kg]
9102646 26.5 435 2450 6320 550 91.76
9102111 29,31 450 2435 6670 900 78.34

 

Material
Al-alloy, steel, stainless steel, EPDM
Surface protection
Steel hot dip galvanized
Use
Interfacial spacer dampers are used on overhead lines in situations, where is not able to keep necessary distance between conductors mainly from following reasons: during the building or construction of the lines with themselues could be reduced appliciated distances between conductors, for existing lines are assembled on the places with enhanced risk of frost cover, which caused enormous galloping of the conductors at her release.
Note
In cooperation with the project manager of the line we can develope variant according to the concrete line.

 

 

Type Conductor diameter [mm] a [mm] b [mm] L [mm] L1 [mm] Weight [kg]
9102992 28.7 450 3195 7700 510 57.84

 

Material
Al-alloy, steel, stainless steel, EPDM
Surface protection
Steel hot dip galvanized
Use
Interfacial spacer dampers are used on overhead lines in situations, where is not able to keep necessary distance between conductors mainly from following reasons: during the building or construction of the lines with themselues could be reduced appliciated distances between conductors, for existing lines are assembled on the places with enhanced risk of frost cover, which caused enormous galloping of the conductors at her release.
Note
In cooperation with the project manager of the line we can develope variant according to the concrete line.

 

 

Type Conductor diameter [mm] L [mm] Weight [kg]
237275.1 30.0 - 32.0 400 8.55

 

Material
Al-alloy, steel, stainless steel, EPDM
Surface protection
Steel hot dip galvanized
Use
Side set of interfacial spacer is used on overhead lines in situations, where is not able to keep necessary distance between conductors mainly from following reasons: during the building or construction of the lines with themselues could be reduced appliciated distances between conductors, for existing lines are assembled on the places with enhanced risk of frost cover, which caused enormous galloping of the conductors at her release.
Note
In cooperation with the project manager of the line we can develope variant according to the concrete line.

 

 

Type a [mm] b [mm] c [mm] e [mm] f [mm] g [mm] L [mm] M1 M2 ∅d ∅D beta [°] Mu1 [Nm] Mu2 [Nm] Weight [kg]
136400.1 8 20 42 74 100 50 155 10 20 23.5 23 - 36 12 43 150 2.90
136400.2 8 20 42 74 100 50 155 10 20 23.5 23 - 36 26 43 150 2.95
136400.3 8 20 42 74 100 50 155 10 20 23.5 23 - 36 43 43 150 3.12
136400.9 8 20 42 74 100 50 190 10 20 23.5 23 - 36 12 43 150 3.15
136400.10 8 20 37 74 100 50 158 10 18 19.5 23 - 36 - 43 100 2.60
136400.12 8 20 37 74 100 50 205 10 18 19.5 23 - 36 - 43 100 3.02
136400.15 8 18 30 74 100 50 140 10 18 19.5 23 - 36 13 43 100 2.50
136400.32 8 20 42 74 100 50 155 10 20 23.5 23 - 36 14 43 150 2.90
136401.2 8 18 36 96 120 60 140 12 18 19.5 36 - 51 12.5 75 100 3.57
136403 8 18 37 96 120 50 155 12 18 19.5 36 - 51 30 75 100 3.40

 

Material
Forged pieces from Al-alloy, steel
Surface protection
Steel hot dip galvanized
Use
Clamps are used in interfacial spacers on 110 kV lines in combination with plastic insulator for determination of necessary distance between conductors and for anti galloping of conductors.
Note
In cooperation with the project manager of the line we can develope variant according to the concrete line.