Bolted strain clamps

Type Conductor diameter [mm] a [mm] c [mm] d [mm] M [mm] Number of U-bolts Strenght of attachment [kN] Weight [kg]
143105 5.40 - 9.50 166 15 12 10 3 14 1.54
143107 5.40 - 12.00 208 20 18 10 3 22 2.28
143107.1 5.40 - 12.00 195 18 16 10 3 22 2.24
143112 12.10 - 16.00 235 20 18 12 4 43 4.31
143635 24.00 - 28.20 280 20 19 12 3 44 5.5
143635.1 24.00 - 28.20 280 20 16 12 3 44 5.45
143867 35.00 - 38.00 330 20 22 16 4 82 10.14
143867.1 35.00 - 38.00 330 20 19 16 4 82 10.09

 

Material
Malleable cat iron, steel
Surface protection
Hot dip galvanized
Use
Anchoring of the Cu and ASCR conductors at overhead lines towers. Types 143 635, 143 635.1, 143 867 and 143 867.1 are designed for high voltage and ultra high voltage substations

 

 

Type Conductor diameter [mm] a [mm] c [mm] d [mm] M [mm] Number of U-bolts Strenght of attachment [kN] Weight [kg]
143108 5.40 - 12.00 120 20 18 10 3 22 1.79
143108.1 5.40 - 12.00 120 20 16 10 3 22 1.71
143114 12.10 - 14.25 135 20 16 12 4 43 3.35

 

Material
Malleable cat iron, steel
Surface protection
Hot dip galvanized
Use
Anchoring of the Cu and ASCR conductors at overhead lines towers. Types 143 635, 143 635.1, 143 867 and 143 867.1 are designed for high voltage and ultra high voltage substations

 

 

Type Conductor diameter [mm] a [mm] c [mm] d [mm] M [mm] Number of U-bolts Strenght of attachment [kN] Weight [kg]
144107 5.4 - 12.0 112 22 19 10 3 33 0.80
144107.1 5.4 - 12.0 112 22 16 10 3 33 0.81
144110 9.0 - 16.0 120 22 19 10 3 50 0.89
144110.1 9.0 - 16.0 120 22 16 10 3 50 0.85

 

Material
Aluminium alloy, steel
Surface protection
Steel hot dip galvanized
Use
Anchoring of the Al and ASCR conductors at overhead lines towers

 

 

Type Conductor diameter [mm] a [mm] c [mm] d [mm] M [mm] Number of U-bolts Strenght of attachment [kN] Weight [kg]
144110.4 9.0 - 16.0 215 20 19 10 3 50 1.78

 

Material
Aluminium alloy, steel
Surface protection
Steel hot dip galvanized
Use
Anchoring of the Al and ASCR conductors at overhead lines towers

 

 

Type Conductor diameter [mm] a [mm] c [mm] d [mm] M [mm] Number of U-bolts Strenght of attachment [kN] Weight [kg]
144197 20.0 - 22.5 200 20 19 16 4 100 4.22
144197.1 22.5 - 25.0 200 20 19 16 4 100 4.1
144197.2 18.0 - 21.0 200 20 19 16 4 100 4.22
144197.5 18.0 - 21.0 200 20 16 16 4 100 4.1
144200.9 29.0 - 35.0 237 20 19 16 4 72 5.89
144201.1 32.0 - 36.5 237 20 16 16 4 80 5.70
144201.3 32.0 - 36.5 237 20 19 16 4 120 5.97

 

Material
Aluminium alloy, steel
Surface protection
Steel hot dip galvanized
Use
Anchoring of the Al and ASCR conductors at overhead lines towers